Cross TalkInfoSheet: - Artifacts - 
Intro, 
Artifacts, 
ReductionMRI Resource Directory:<br> - Artifacts -
 
Cross talk is an ultrasound artifact in which strong sound signals in one directional channel leak into another, appearing as a mirror image of the spectral display on the opposite side of the baseline. Cross talk distinguishes the condition of undesired crossover of transmitted sound waves into the receiving transducer in a continuous wave Doppler system.
Also called Mirror Artifact.
spacer
• Related Searches:
    • Partial Volume Artifact
    • Apodization
    • Wall Filter
    • Aliasing Artifact
    • Acoustic Mismatch

 Further Reading:
  News & More:
Space-time encoding for high frame rate ultrasound imaging.Open this link in a new window
May 2002   by www.ncbi.nlm.nih.gov    
Doppler Mirror Image Artifacts Mimicking Mitral Regurgitation in Patients with Mechanical Bileaflet Mitral Valve ProsthesesOpen this link in a new window
   by ejechocard.oxfordjournals.org    
Searchterm 'Cross Talk' was also found in the following service: 
spacer
MRI  (3) Open this link in a new window
Acoustic ImpedanceMRI Resource Directory:<br> - UltraSound Physics -
 
(Z) The acoustic impedance is dependent on the density of the material in which sound is propagated through. When an ultrasonic wave crosses an interface between tissues with different acoustic impedance, the wave divides in 2 components, and the energy of the reflected components directly relates with the acoustic impedance.
The greater the impedance the more dense the material, and the greater the difference in acoustic impedance between two adjacent tissues the more reflective will be their boundary.
The acoustic impedance (the unit is "Rayl") is the product of the sound velocity and the physical dense.
The acoustic impedance is very high between air or bone and other body tissues, therefore not enough energy crosses these interfaces, and no information can be collected from organs placed behind them.
See also Mirror Artifact, Reverberation Artifact, Cross Talk and Ultrasound Physics.
Radiology-tip.comLinear Energy Transfer,  Photoelectric Effect
spacer
Radiology-tip.comSkin Depth,  Magnetic Susceptibility
spacer

 Further Reading:
  Basics:
Ultrasound Physics Main differences between Ultrasound and X-rays, Velocity of sound in some Biological MaterialsOpen this link in a new window
   by www.drgdiaz.com    
Physics Tutorial: Ultrasound PhysicsOpen this link in a new window
   by www.physics247.com    
  News & More:
ACOUSTIC CARACTERIZATION OF ULTRASOUND CONTRAST AGENTSOpen this link in a new window
2007   by etd.adm.unipi.it    
US Resources  
DICOM - Databases - Education - UltraSound Technician and Technologist Jobs - PACS - Research Labs
 
Continuous Wave DopplerInfoSheet: - Modes - 
Intro, 
Overview, 
Types of, 
etc.MRI Resource Directory:<br> - Modes -
 
(CWD) Continuous wave (CW) Doppler is an ultrasound imaging mode, which records blood flow velocities along the length of the beam. Continuous wave Doppler uses different crystals to send and receive the signal. The transducer operating in continuous wave mode utilizes one half of the elements and is continuously sending sound waves of a single frequency while the other half is continuously receiving the reflected signals.
The advantages of a continuous wave transducer are a high sensitivity and no Nyquist limit. CW Doppler does not alias but has no depth precision and large gate. The beat frequency is the Doppler shift. CW Doppler echocardiography employs this technique to record the flow of blood through the cardiovascular system.
See also Cross Talk, Periorbital Doppler, and Mirror Artifact.
spacer

 Further Reading:
  Basics:
Basic ultrasound for cliniciansOpen this link in a new window
March 2006   by folk.ntnu.no    
  News & More:
Optimization of ultrasound-mediated gene transfer: comparison of contrast agents and ultrasound modalities1Open this link in a new window
Sunday, 27 July 2003   by eurheartj.oxfordjournals.org    
Placental insufficiency and fetal heart: Doppler ultrasonographic and biochemical markers of fetal cardiac dysfunctionOpen this link in a new window
   by herkules.oulu.fi    
US Resources  
Education pool - Non-English - Manufacturers - Carotid - Databases - Abdominal
 
Mirror ArtifactInfoSheet: - Artifacts - 
Intro, 
Artifacts, 
ReductionMRI Resource Directory:<br> - Artifacts -
 
The mirror artifact is similar to the reverberation artifact. Mirror image artifacts (mirroring) can occur if the acoustical impedances of the tissue is too much different and the ultrasound is reflected multiple times on tissue layers. The echo detected does not come from the shortest sound path, the sound is reflected off an angle to another interface so that like a real mirror, the artifact shows up as the virtual object.
An empyema or lung abscess can be simulated by a mirror image artifact of a hepatic cyst. This liver lesion can appear like a lesion within the lung because the wave is reflected off the diaphragm back into the liver. The angle of reflection is equal to the angle of incidence. The sound pulse hits the interfaces within the liver lesion and is reflected back to the diaphragm once again with an angle of reflection equal to the angle of incidence and then back to the transducer.
Also by a pelvic ultrasound scan the sound can be reflected off the rectal air at an angle so that the deep wall of an artifactual cyst represents the mirror image of the inferior and anterior walls of the bladder. Mirror image artifacts can cause other strange appearances such as invasion of a transitional cell carcinoma through the bladder wall.
Also called Cross Talk.
spacer

 Further Reading:
  Basics:
Ultrasound artifactsOpen this link in a new window
   by rad.usuhs.mil    
  News & More:
Doppler Mirror Image Artifacts Mimicking Mitral Regurgitation in Patients with Mechanical Bileaflet Mitral Valve ProsthesesOpen this link in a new window
   by ejechocard.oxfordjournals.org    
Transmission Line Matrix (TLM) modelling of medical ultrasound(.pdf)Open this link in a new window
   by www.era.lib.ed.ac.uk    
Searchterm 'Cross Talk' was also found in the following service: 
spacer
MRI  (3) Open this link in a new window
Related Searches:
 • Apodization
 • Frame Averaging
 • Acoustic Mismatch
 • Retrolenticular Afterglow
 • Rayleigh Scattering
SEARCH FOR   
 
  12345ABCDEFGHIJKLMNOPQRSTUVWZ
     1 - 4 (of 4)     
Result Pages : [1]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

US-TIP    
Community   
User
Pass
Forgot your UserID/Password ?  


Look
      Ups



UltraSound - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • US-TIP • The-Medical-Market
Copyright © 2006 - 2014 SoftWays. All rights reserved.
Terms of Use | Privacy Policy | Advertising
 [last update: 2014-07-21 03:08:21]